Optic Nerve Head Image Database (ODTiD)
Principal Investigator(s): View help for Principal Investigator(s) Jothi Balaji Janarthanam, Senior Manager; Lakshminarayanam Vasudevan, Professor
Version: View help for Version V2
Name | File Type | Size | Last Modified |
---|---|---|---|
|
application/x-rar-compressed | 37.7 MB | 04/14/2021 08:57:PM |
|
application/x-rar-compressed | 45.5 MB | 04/14/2021 08:38:PM |
|
application/vnd.openxmlformats-officedocument.spreadsheetml.sheet | 16.4 KB | 04/14/2021 11:02:PM |
Project Citation:
Janarthanam, Jothi Balaji, and Vasudevan, Lakshminarayanam. Optic Nerve Head Image Database (ODTiD). Ann Arbor, MI: Inter-university Consortium for Political and Social Research [distributor], 2021-04-15. https://doi.org/10.3886/E137701V2
Project Description
Summary:
View help for Summary
The Optic Disc tilt (ODT) or Tilted optic disc is a common finding in the general population and it is due to anomalous ocular development caused by the malclosure of the embryonic optic fissure. ODT is commonly associated with high myopia as well as other conditions (e.g., astigmatism, visual field loss, defective color vision, and retinal abnormalities). This dataset of ODT images contains both horizontal and vertical cross-sectional images obtained using Spectral-Domain Optical coherence tomography (SD-OCT, Cirrus 5000, Carl Zeiss Meditec Inc., Dublin, CA). The optic disc cube 200 x 200 program was used and all the images are aligned with the center of the optic nerve head. All OCT images are 8-bit grayscale images of dimensions of 200 x 200 pixels corresponding to 6 mm x 6 mm (894 x 596 pixels). These datasets cover both clinically normal (20 eyes) and myopic subjects (101 eyes). For each type of image, clear and manually segmented by a clinical expert (ground truth) are available. Additional information includes, age, gender, laterality, refractive error classification, spherical equivalent, best corrected visual acuity, intraocular pressure and axial length. This dataset can be used to test and validate newly developed automated segmentation algorithms.
Funding Sources:
View help for Funding Sources
Partly supported by a Discovery grant from the Natural Sciences and Engineering Research Council of Canada (V.L.)
Scope of Project
Subject Terms:
View help for Subject Terms
Optic Disc;
Myopia;
Image Segmentation;
Image Database;
Ophthalmology;
Optical Coherence Tomography
Geographic Coverage:
View help for Geographic Coverage
India
Collection Date(s):
View help for Collection Date(s)
1/2019 – 12/2020
Data Type(s):
View help for Data Type(s)
clinical data;
images: photographs, drawings, graphical representations
Related Publications
This study is un-published. See below for other available versions.
Published Versions
Report a Problem
Found a serious problem with the data, such as disclosure risk or copyrighted content? Let us know.
This material is distributed exactly as it arrived from the data depositor. ICPSR has not checked or processed this material. Users should consult the investigator(s) if further information is desired.